流式分选液滴延迟校准微球-用于细胞分选的时间延迟校准
2025-04-18SPHERO™ Drop Delay Calibration Particles
- Particles for fine tuning cell sorters that have the appriopriate attachment
- Used to determine the drop delay value
- Improves the accuracy and productivity while sorting
货号 | 品名 | 浓度 | 粒径 | 规格 | 备注 |
SPBY-DDCP-70-2 | Drop Delay Calibration Particles | 108/mL | 6.0-8.0 µm | 2ml | 适用于常规细胞的分选,多个通道均可以设置 |
SPHERO™ AccuCount Ultra Rainbow Fluorescent Drop Delay Calibration Particles for Large Cell Sorting
- Large beads for fine tuning cell sorters that have the appropriate attachment
- Used to determine the Drop-Charge Delay (DCD) and Laser Time Delays (LTD) during larger cell sorting
- Used to determine if the flow of larger particles is unaffected by instrument design
- Allow for the real-time correction of instrumentation variation when sorting large cells between 20-30 µm in Mazel, S, Fang, F., Semova, S. Semova, Georgala, P., and Gardner, R. “Size Matters”: On the Challenges of Sorting Large Cells with Conventional Droplet Cell Sorters. Poster presented at: 1st CYTO ASIA Scientific Conference; 2017 Oct 25-27; Singapore.
货号 | 品名 | 浓度 | 粒径 | 规格 | 备注 |
SPBY-ACURFP50-70-1 | AccuCount UltraRainbow Calibration Particles | 5x107/mL | 7.0 µm (+/-1 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPBY-ACURFP20-100-1 | AccuCount UltraRainbow Calibration Particles | 2x107/mL | 10.0 µm (+/-1 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPBY-ACURFP5-150-1 | AccuCount UltraRainbow Calibration Particles | 5x106/mL | 15.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPBY-ACURFP5-200-1 | AccuCount UltraRainbow Calibration Particles | 5x106/mL | 20.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPBY-ACURFP2.5-250-1 | AccuCount UltraRainbow Calibration Particles | 2.5x106/mL | 25.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPBY-ACURFP2.5-300-1 | AccuCount UltraRainbow Calibration Particles | 2.5x106/mL | 30.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,多个通道均可以设置 |
SPHERO™ AccuCount Fluorescent Drop Delay Calibration Particles for Large Cell Sorting
- Large beads for fine tuning cell sorters that have the appropriate attachment
- Used to determine the Drop-Charge Delay (DCD) and Laser Time Delays (LTD) during larger cell sorting
- Labeled with a different fluorophore, Nile Red, than the AccuCount Ultra Rainbow Fluorecent Drop Delay Calibration Particles for Large Cell Sorting, but with matching diameters and concentration
- Allow for the real-time correction of instrumentation variation when sorting large cells between 20-30 µm in Mazel, S, Fang, F., Semova, S. Semova, Georgala, P., and Gardner, R. “Size Matters”: On the Challenges of Sorting Large Cells with Conventional Droplet Cell Sorters. Poster presented at: 1st CYTO ASIA Scientific Conference; 2017 Oct 25-27; Singapore.
货号 | 品名 | 浓度 | 粒径 | 规格 | 备注 |
SPBY-ACFP50-7056-1 | AccuCount Fluorescent Particles | 5x107/mL | 7.0 µm (+/-1 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
SPBY-ACFP20-10056-1 | AccuCount Fluorescent Particles | 5x107/mL | 10.0 µm (+/-1 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
SPBY-ACFP5-15056-1 | AccuCount Fluorescent Particles | 5x106/mL | 15.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
SPBY-ACFP5-20056-1 | AccuCount Fluorescent Particles | 5x106/mL | 20.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
SPBY-ACFP2.5-25056-1 | AccuCount Fluorescent Particles | 2.5x106/mL | 25.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
SPBY-ACFP2.5-30056-1 | AccuCount Fluorescent Particles | 2.5x106/mL | 30.0 µm (+/-2 µm) | 1 mL | 适用于大型细胞的分选,带荧光(Nile red)通道用 |
830 | Time Delay Calibration Standard | 108/mL | 6 µm | 1 mL | 适用于常规细胞的分选,红色/远红外通道设置 |